NO TE
For specic qualication requirements, see local laws, regulations, and industry
standards.
Figure 1-1 Wearing PPE
Before installing, operating, or maintaining the equipment, remove conductive
objects such as watches, bracelets, bangles, rings, and necklaces to prevent
electric shock.
During transportation, transfer, installation, cable connection, and
maintenance, comply with the national and local laws, regulations, and
relevant standards.
Personnel must be familiar with the structure and working principles of the
entire ESS, and perform operations according to the manual.
1.3 Electrical Safety
Cabling
Do not perform any improper operations, for example, dropping cables
directly from a vehicle.
Do not route cables through air intake or exhaust vents of the equipment.
Bind cables of the same type together. When routing cables of
dierent types,
ensure that they are at least 30 mm away from each other.
When cable connection is completed or paused for a short period of time, seal
the cable holes immediately with the sealing mud to prevent small animals
from entry.
When routing cables, reserve at least 30 mm clearance between the cables
and heat-generating components or areas. This prevents deterioration or
damage to the cable insulation layer.