Loading...
Figure 11-1 The Upper Part of the Lock Tongue Interferes With the Upper Surface
of the Lock Base
(1) Position of leveling washers
Scenario 2: The Lower Part of the Lock Tongue Interferes With the Lower Surface
of the Lock Base
Use leveling washers to raise ESS by 5–10 mm on the foundation under the lock
base farthest to the door hinge.
Figure 11-2 The Lower Part of the Lock Tongue Interferes With the Lower Surface
of the Lock Base
(1) Position of leveling washers
----End
11.2 How to Ensure that the Solenoid Valve Is Not
Activated
Step 1 Check whether the solenoid valve is not activated.
Step 2 If it is activated, reset it. The reset procedure is as follows: