2. In the File Storage Service area, click Share.
3. Select all le systems recorded in Step 3.3 one by one and record the share
path to which each le system maps. Stop the services running on the share
path on the host.
Step 5 Determine the hosts to which these LUNs map.
1. In the navigation tree, click Provisioning.
2. In the Block Storage Service area, click
Host.
3. Select the hosts whose Added to Host Group is Yes. In the Mapped LUNs tab
below, check whether the LUN recorded in Step 3.3 exists.
– If yes, there are services related to the system subrack running on this
host. Stop the services running on the LUN on the host.
– If no, go to Step 3.3 until the services on all recorded LUNs are stopped
on the host. Then replace the system subrack.
----End