If using a manual Dataset
®
arm, press the “Next” button (if
necessary) to change display to show distance to the weight plane (right
or left) for the weight being placed.
Pull Dataset
®
arm out until the scale reading and the display right plane
distance reading are the same.
Find BDC for right plane as shown below.
Attach adhesive weight at BDC in-line with the Dataset
®
arm disc edge, using Servo
Aided Weight Placement or manual Dataset
®
arm as described above.
RIGHT PLANE BDC
(BLINKING)
If necessary, use the “Right Plane Split Weight
®
” to split weight.
Verify balance condition by spinning again. Display should show “zero.”
Balancing procedure is complete.
DSP9200 Series Balancer Operation Instructions 3. Balancing a Wheel