Place the calibration tool on the shaft using the middle spindle shaft slot. Align the
center hole of the calibration tool with a calibration weight thread hole, and tighten
the calibration weight securing the calibration tool to the hub face as shown below.
CAUTION: Do NOT operate balancer with calibration tool attached.
Remove calibration tool immediately after performing this
procedure.
Press “OK” when calibration tool is installed.
Rotate the calibration tool slowly by hand, clockwise until the GSP9720JLR beeps.
NOTE: You may have to rotate the tool up to 1 1/2 turns.
Position the calibration tool parallel to the floor. Tap the foot pedal once or press “OK.”
NOTE: To verify that the tool is parallel to the floor, measure from
both ends of the calibration tool to the floor. The
measurement will be the same at both ends when the tool is
parallel to the floor.
122
x
Calibration and Maintenance GSP9720JLR Wheel Balancer Operation Instructions