ADHESIVE WEIGHTS Balancing Procedure Using Adhesive Weights
Verify that the wheel is clean and free of debris.
Remove all previous weights.
Mount tire/wheel assembly. Refer to “Mount the Wheel on the Spindle Shaft,”
page 25.
Press
. Use the arrows to select “ADHESIVE WEIGHTS BALANCE” and
press “OK.”
Select either grams or ounces by rotating the control knob and highlighting either “g”
or “oz.”
Select “DYNAMIC” by rotating the control knob to highlight “
.” Refer to “Dynamic
Balancing,” page 47.
Using the DOWNWARD position, place the inner Dataset® arm disk edge to the
outermost location for placement of the right edge of the left adhesive weight and
enter the data by depressing the foot pedal. Refer to “Using the Auto Dataset®
Arms,” page 59.
Do NOT return the inner Dataset® arm to the “home” position.
Using the DOWNWARD position, move the inner Dataset® arm disk edge to the
innermost location for placement of the right edge of the right adhesive weight and
enter the data by depressing the foot pedal. Refer to “Using the Auto Dataset®
Arms,” page 59.
Close safety hood.
Press the green “START” button if “Hood Autostart” is disabled.
After wheel comes to a complete stop, raise the safety hood.
Servo-Activated Laser automatically locates BDC to aid in fast adhesive weight
positioning.
GSP9720JLR Wheel Balancer Operation Instructions Balancing Procedures
55