36  BALANCING PROCEDURES
Dimensions Entry - Outer Clip
Pulling out only the outer Dataset® arm after already 
measuring an inner clip dimension signals to the balancer 
that the operator wants to measure an outer plane clip 
dimension. 
Figure 130. 
Dimensions Entry - Inner and Outer Clip
Pulling out both the inner and outer Dataset® arms 
and placing them in the clip-clip position signals to the 
balancer that the operator wants to measure inner and 
outer plane clip dimensions. 
Figure 131. 
Balancing Procedure Using Clip-On Weights
Figure 132. 
Dimensions Entry - Outer Tape
Pulling out only the inner Dataset® arm, pointing 
it down and pressing on the foot pedal records the 
first dimension. Since the Dataset® arm is still in the 
down position, this signals to the balancer that the 
operator wants to measure the second inner plane tape 
dimension. 
Figure 128. 
Dimensions Entry - Enter Spoke(s)
Entering an outer plane tape dimension will prompt 
operator to enter spoke positions so that tape weight(s) 
can be hidden behind spoke(s). 
Figure 129. 
The operator can enter the spoke(s) location(s) or return 
the Dataset® arm to its home position to cancel spoke 
location entry.