Excelon XD/XQ Operators Manual 85
Realtime Edging Window (expr)
Realtime Edging Window Show edging progress window when edging
started.
Progress Bar Only Show only edging steps
Disable processed job editing
Processed job cannot be modified.
Show Blocking Offset
Shows manual blocker guide line on the frame area (Boxing center.only)
Digital PTN Apply Method
Select FPD/Bridge Size recalculation method when frame shape changed
by Digital Pattern
Turn Off Job Merge Warning
Turn off the duplication of the job warning message
6.1.2 Layout Default
Default Side
Select default lens side.
Layout mode
Select default lens type (Normal lens, bifocal lens, bifocal(blend) lens)
Blocking Mode
Select default blocking mode (Boxing Center, Optical Center)
OH type
Select default OH type (Delta Y, Box Height, Mix Height)
Default Value (PD, Delta Y, Bridge Size)
Input default values
Bifocal Offset
Input default blocking offset of the bifocal lens.
Bifocal Lens Size
Input default size of near vision area.
R/L Sync