6.1.4 Hole Editor Default (XD)
X Pos Reference/ Y Pos Reference
Select default hole position coordinates reference
X (Horizontal) frame center / temporal box / nasal box
Y (Vertical) frame center / Top box / Bottom Box
Tilting Angle Mode
Set default titling mode (auto, manual)
Tilting Ref Surface
Select default tilting reference surface (front, back)
Default Value (Depth, Diameter, tilting angle)
Set default values
Confirm Hole Delete
Show confirm dialog box when the hole delete button pressed.
Hole Data Loading Type
Select hole data loading method
Use Hole Data Preset
Show hole data preset buttons in the hole editor screen
Confirm preset load
Show confirm dialog box when the hole preset button pressed.
Use Demo Lens Curve (Automatic correction of hole position)
Apply demo lens curve value for drilling
Default Demo Lens Curve
Set default demo lens curve value
Drill Bit Warning Message
Show warning message when the diameter of the hole is smaller than the
drill bit.
Digital Ptn : Coordinates Compensation
Select compensation method of the Digital Patterned hole data.
Enable Hole Retouch Mode
Enable Drilling Retouch.