2.2
MANUAL MODE ONLY CONTROLS
HEAD CONTROLS
HEAD UP Pressing this key will raise the head but it will stop and hold its position if the key is re-
leased.
HEAD DOWN Pressing this key will lower the head to its bottom limit and will stop and hold its position
when pressed again, or if the HEAD UP key is pressed.
FIXED VISE CONTROLS
FIXED VISE OPEN Pressing this key will open the xed (front) vise and will stop and hold its position if the
key is released.
FIXED VISE CLOSE Pressing this key will close the xed (front) vise. To stop and hold its position, press
again or press the FIXED VISE OPEN key.
SHUTTLE VISE CONTROLS
SHUTTLE VISE OPEN Pressing this key will open the shuttle (rear) vise and will stop and hold its position if the
key is released.
SHUTTLE VISE CLOSED Pressing this key will close the shuttle (rear) vise. To stop and hold its position, press
again or press the SHUTTLE VISE OPEN key.
SHUTTLE CONTROLS
SHUTTLE FORWARD Pressing this key will move the shuttle towards the front of the saw and will stop and hold
its position if the key is released.
SHUTTLE REVERSE Pressing this key will move the shuttle towards the back of the saw and will stop and hold
its position if the key is released.
SHUTTLE SLOW / FAST Pressing this key will cause the shuttle to move either fast or slow. The red LED indicates
that the shuttle will move FAST. Pressing the key will switch this function back to SLOW.
MANUAL & AUTO MODE CONTROLS
BLADE CONTROLS
BLADE START Pressing this key will start the blade. The blade will not start if the head is fully down.
BLADE STOP Pressing this key will stop the blade.
BLADE SPEED (+) Pressing this key will cause the blade speed to increase until the key is released or the
speed is at the maximum (350 SFM). The blade must be running to use this key and the
blade speed is shown on the display screen.
BLADE SPEED (-) Pressing this key will cause the blade speed to decrease until the key is released or the
speed is at the minimum (70 SFM). The blade must be running to use this key and the
blade speed is shown on the display screen.
COOLANT CONTROLS
COOLANT ON Pressing this key will start the coolant ow.
COOLANT OFF Pressing this key will stop the coolant ow.
COOLANT AUTO Pressing this key will cause the coolant to ow only when the blade is running OR when
the blade is running and the head is descending. This is selectable via the PLC param-
eters in the SERVICE MODE.
NOTE: There are two types of SHUTTLE OVER TRAVEL protection: Software and Hardware.
Shuttle home routine needs to be completed before the software over travel function will operate properly. It will stop
shuttle movement on each end of the shuttle stroke before actuating hardware over travel. If shuttle home routine is not
completed then software over travel will not operate properly and the over travel limit switch (Hardware over travel) will
stop shuttle movement.

Table of Contents