3.11
11 Excessive blade breakage. 11.1 Band tension too high 11.1 Check blade tension display
- adjust tension to between 1000
- 1200 kg
11.2 Excessive feed force. 11.2 See 6.1
12 Blade tooth strippage. 12.1 Gullet packing - blade pitch too
ne.
12.1 Refer to Saw Cutting Parameter
Chart for correct pitch.
12.2 Gullet packing - blade brush not
cleaning.
12.2 Adjust or replace blade brush.
12.3 Excessive feed force. 12.3 See 6.1
13 Blade dulls too quickly. 13.1 Blade speed too high. 13.1 Refer to Saw Cutting parameters
Chart.
13.2 Excessive feed force. 13.2 See 6.1
13.3 Wrong blade for workpiece
material.
13.3 Seek advice ofblade supplier or
Hyd-Mech dealer.
13.4 Ineffective cutting uid. 13.4 Check uid cleanliness and
concentration.
Seek advice of uid supplier or
Hyd-Mech dealer.
14 No or low cutting uid ow. 14.1 Fluid level in tank is too low. 14.1 Add cutting uid.
14.2 Fluid line(s) blocked. 14.2 Clear line(s) with compressed air.
Wear suiutable eye protection
14.3 Cutting uid pump not running. 14.3.1 Check contactor overload, reset if
necessary.
14.3.2 Check fuse 5FU2, replace if
necessary.
14.4 Cutting uid pump running, but
not pumping.
14.4.1 Tilt and shake pump, while
running to clear air and assist
priming.
14.4.2 Shut-down and remove pump,
check for blockages.
Check that impeller is intact,
replace pump if necessary.

Table of Contents