MAINTENANCE
8-18 HySpeed HT2000 Instruction Manual
19
Problem Possible Causes / Solutions
7. COOLANT FLOW LED
illuminated:
7.1. Coolant flow restricted.
This LED will extinguish when flowswitch (FS1) senses a
coolant flow of at least 0.5 gpm (1.9 l/m) to the torch. FS1 is
a normally open switch that closes when a flow greater than
0.5 gpm is sensed. See Coolant Flow Test Procedure later
in this section to troubleshoot coolant flow problems.
Note: Coolant flow LED illuminates when line disconnect
switch is turned ON because coolant reservoir pump M2 is
not activated until the power supply POWER ON (PB1) is
pressed.
Using the wiring diagrams, check pins, wires and
connections from TS2 to PCB1.
Repair and/or replace defective component(s), if necessary.