OPERATION: ARGON-HYDROGEN MANIFOLD
7-6 HySpeed HT2000 Instruction Manual
19
WARNING
Before operating this system, you must read the Safety section thoroughly!
Verify main disconnect switch to the HT2000 power supply is OFF before proceeding with the
following steps.
Operation
Prior to operation, ensure that your cutting environment and that your clothing meet the safety requirements
outlined in the Safety section of this manual. If problems occur during operation, refer to the Installation
portion of this section as well as Section 4.
Note: For operation without
argon-hydrogen manifold, see Section 6: Operation.
Check Torch
1. Remove the consumables from the torch and check for worn or damaged parts. Always place the
consumables on a clean, dry, oil-free surface after removing. Dirty consumables can cause the
torch to malfunction.
• Check the pit depth of the electrode. The electrode should be replaced when the depth exceeds
.040 inch (1 mm).
• Wipe the current ring in the torch with a clean paper towel or Q-tip (see Figure 6-7).
• Refer to the Cut Charts to choose the correct consumables for your cutting needs.
2. Replace consumable parts. Refer to Changing Consumable Parts in Section 6 for detailed information on
replacing consumables.
3. Ensure that the torch is squared to the material. Refer to Section 4 for the torch alignment procedure.
4. Verify that argon-hydrogen cable 14X1 is connected to the argon-hydrogen manifold.
Turn Gases On
1. Set S2 toggle switch on the gas console to Run.
2. Set S1 switch to N2/Air position.
3. Turn the argon-hydrogen gas supply and the nitrogen gas supply ON.
Verify that the oxygen and air gas supplies remain OFF.
• Adjust the argon-hydrogen plasma gas supply regulator to read
120 psi +/- 10 psi (8.2 bar +/- 0.7 bar).
• Adjust supply regulator for shield gas to read 90 psi +/- 10 psi
(6.2 bar +/- 0.7 bar).
S1
S2