PRE-INSTALLATION
3-8 HySpeed HT2000 Instruction Manual
19
220/380/400/415V Transformer T1 and T2 Configurations
The 220/380/400/415-volt, 3PH, 50 Hz power supply is normally shipped from the factory set up for 380-volt
operation, unless otherwise specified. To change the power supply to a different voltage, the control
transformer T1 and 30 kw transformer T2 must be re-configured (see Figure 3-2).
* A long #6 AWG 600V wire is shipped with every unit.
Figure 3-2 220/380/400/415V Transformer T1 and T2 Configurations – 1 of 2
T1
T1
T2
T2