MAINTENANCE AND REPAIR
powermax
65/85
Operator Manual 5-5
Problem Solutions
The arc blows out, but re-ignites when
the torch trigger is pressed again.
Inspect the consumable parts and replace them
if they are worn or damaged. See “Inspect the
consumables” on page 5-3.
Replace the gas filter’s element if it is
contaminated. See “Replace the gas filter
element” on page 5-10.
Make sure the gas pressure is at the proper level.
The arc sputters and hisses. The gas filter’s element is contaminated. Replace
the element. See “Replace the gas filter element”
on page 5-10.
Inspect the gas line for moisture. If necessary,
install or repair the gas filtration to the power
supply. See “Prepare the gas supply” on page 2-14.
The cut quality is poor. Verify that the torch is being used correctly. See
Section 4, Operation.
Inspect the consumables for wear and replace
as necessary. See “Inspect the consumables” on
page 5-3.
Check the air pressure and air quality.
Verify that the cutting mode switch is in the
proper position for the cutting operation.
Verify that the correct consumables are installed.

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals