TORCH SETUP
powermax
65/85
Operator Manual 3-45
85A Unshielded Air flow rate - slpm/scfh
Stainless Steel
Hot 190 / 400
Cold 235 / 500
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1
8550 117 14000 114
3 7000 118 12000 116
4 0.2 5600 118 9800 118
6
0.5
3400 120 5700 122
8 2250 121 3700 124
10
6.0 300
0.5 1430 123 2300 125
12 0.7 1000 129 1700 127
16
Edge Start
650 134 910 131
20 360 138 720 136
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
14GA
0.08
0.20 250
0.1 365 117 580 114
10GA
0.2
280 120 460 116
3/16 in 200 123 335 118
1/4 in
0.5
110 126 215 119
3/8 in 75 127 110 123
1/2 in 0.24 300 0.6 45 135 78 128
5/8 in
Edge Start
34 139 56 132
3/4 in 22 143 40 136

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelPowermax 85
CategoryWelding System
LanguageEnglish

Related product manuals