Wiring Diagrams
8-2 powermax
45
Service Manual
FAULT
YEL
AMPS
CW
CAPOFF
YEL
"TSO/TSC"
AC PWR
GRN
"L/H LINE"
720
IN
15
IN
9
V-
8
IN
7
IN
13
IN
12
IN
11
IN
10
IN
6
V+
16
IN
3
IN
2
IN
1
IN
5
IN
14
IN
4
JTAG
1
3
5
7
9
11
13 14
2
4
6
8
10
12
12
34
56
78
910
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
2
1
3
4
56
7
ON
ON
CASE
CASE
1
2
3
4
TEMP
YEL
L
R
1
ERROR
CODE
.25"
FOR
BD
DEPAN-
IZATION
SERIAL
DATA
MACHINE
FRONT
DSP 2806
4x25Mhz=100Mhz
0.78 x 0.78"
Stayout for
TEST CLIP
/RESET or
HDR FLT
START
XFR
GAS
CONTROL PWA
CPA (UP)
NORMAL (MIDDLE)
GOUGE (DOWN)
YEL
YEL
GRN
"SETPOINT"
GRN
GRN
MODE
45 A 230 V
Control board diagram: 200–240V CSA and 230V CE
J7 pin number to ground Test
Expected value
(200–240V CSA or 230V CE)
19
VACR (rectified AC line
voltage)
1.95V at 230 line voltage
21 VBUS (DC bus voltage) 2.28VDC at 385VBUS
18
(200–240 and 230V only)
IPFC (input current) < 0.1VDC
20 IFB (output current) < 0.1VDC
22 ITF (transfer current) < 0.1VDC
25 3.3VDC 3.3VDC ±5%
24 5VDC 5VDC ±5%
12 24V sense pin 2.2VDC
16 Start signal
3.2VDC closed
0VDC open

Table of Contents

Other manuals for Hypertherm powermax45

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm powermax45 and is the answer not in the manual?

Hypertherm powermax45 Specifications

General IconGeneral
BrandHypertherm
Modelpowermax45
CategoryWelding System
LanguageEnglish

Related product manuals