72 hysecurity.com | 800-321-9947 StrongArm Programming and Operations
Installer Menu Setting Options Menu Tasks & Explanations STC Wire
Connections
LT 3 (75 SECS)
LOITERING ALERT
0 = 0s delay
1 = 15s
2 = 45s
3 = 75 second delay
4 = 105s
5 = 135s
Lets you specify when the relay activates.
The relay turns ON when the software
detects that the gate operator has been
off its close limit for the specied period of
time. With updated software versions, LT
appears in the Installer Menu even without
the User Relay option 8 being utilized.
User Relay 8
SA 0 (OFF)
STC ADDRESS
0 = No network
1 to 99 = Network “drop” address
Sets the system address for network
communication. 1 – 99 sets individual poling
addresses.
Refer to HyNet™ literature for more
information.
RS-485. Involves
additional
hardware &
software.
NE 0 (OFF)
NETWORK SETUP
0 = No network (off)
1 = Network address (on)
Menu item appears when SA is not set to
zero (0).
If a system address exists a setting of 1
opens the network conguration menu.
0 = no network communication
1 = allows conguration of network
addresses.
RS-485. Involves
HyNet &
software.
ID 0 HYINVERTER
DIAGNOSTICS
0 = no diagnostics displayed
1 = view diagnostics displays
HYINVERTER INPUT - LINE xxx.x VAC
HYINVERTER TEMP - xxx.xF / xxx.x C
HYINVERTER VOLTS - BATTERY xx.x
VDC HYINVERTER - BATTERY xxx.x %
Controls which system diagnostics appear
on the display. With a setting of 1, you can
access the AC Power Supply with HyInverter
AC diagnostic mode. Use the Next or
Previous buttons, on the gate operator’s
keypad, to view the diagnostics on the STC
display.
NOTE: These same diagnostics appear on
the AC Power Supply with HyInverter AC
display in a constant scrolling format.
AC Power Supply
with HyInverter
AC to STC
(Modbus RTU
communication
protocol via
RS-485.)
ELD0 RUN MODE
EXIT LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY-5B Free Exit loop detector. HY-5B
ILD0 RUN MODE
IND OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY-5B Inside Obstruction Loop
detector.
HY-5B
OLD0 RUN MODE
OUT OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY-5B Outside Obstruction
Loop detector.
HY-5B
RLD0 RUN MODE
RESET LOOP SET
(Shadow Loop Set)
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the HY-5B Shadow/Reset Loop
detector.
HY-5B