Table 38: ASC, and ASCQ summary for Sense Key 7 (Data Protect) (continued)
ASC ASCQ Description
EF C0 Encryption - no operation
Sense Key 8 (Blank Check)
Table 39: ASC, and ASCQ summary for Sense Key 8 (Blank Check)
ASC ASCQ Description
00 05 End-of-data detected
14 01 Record not found, void tape
Sense Key B (Aborted Command)
Table 40: ASC, and ASCQ summary for Sense Key B (Aborted Command)
ASC ASCQ Description
14 00 Recorded entity not found
14 01 Record not found
14 02 Filemark or setmark not found
1B 00 Synchronous data transfer error
43 00 Message error
44 00 Internal target failure
45 00 Select or reselect failure
47 00 SCSI parity error
48 00 Initiator detected error message received
49 00 Invalid message error
4A 00 Command phase error
4B 00 Data phase error
4E 00 Overlapped commands attempted
Sense Key D (Volume Overflow)
Table 41: ASC, and ASCQ summary for Sense Key D (Volume Overflow)
ASC ASCQ Description
00 02 End-of-partition/medium detected
Error Log Analysis - AIX
The AIX
®
Tape and Medium Changer device driver for the AIX provides logging to the system error log for
various errors. Use one of the following AIX commands to view the error log in various formats -
• Tapeutil command on “Tapeutil command” on page 54
• Diag command on “Diag command” on page 54
• SMIT command on “SMIT command” on page 58
Messages
53