5 Remove the SCSI terminator from the connector
on
the back of the
9401
System Unit.
6 Are you installing feature 6365?
No
Yes
Install the terminators by performing the following:
a. The terminator that was removed from the system unit in step 5 is not used.
Store the terminator in a safe place.
b.
Install the terminator that was shipped with the feature into the available SCSI
connector
on
the back of the tape unit.
Go to step 8 of this procedure.
7 You are installing an IBM 3450 Model
001
or an IBM 7207 Model 012.
Install the terminator (that was removed in step 5 of this procedure) to the terminator connector at
the tape unit end of the SCSI cable. See Figure
5-1
on
page 5-
3,
EJ.
8 Connect the system-unit end
IJ
of the SCSI cable to the SCSI connector
on
back of the
9401
System Unit. See Figure
5-1
or Figure 5-2
on
page 5-3.
9 Connect the power cord to the back of the tape unit.
10 Return to step 5
on
page 5-2
in
Chapter
5,
"Install Additional Devices."
Note: For instructions on how to clean the tape unit, see the tape device manual, or the tape unit
section
in
the System Startup
and
Problem Handling book.
This ends the procedure.