Chapter
6.
Perform
an
Initial Program Load
Use the procedures
in
this chapter to perform an IPL on the 9401 System Unit. Ensure that you have
completed the procedures
in
Chapter
5,
"Install Additional Devices" on page 5-1.
1 Open the front cover of the 9401 System Unit (see Figure 2-2 on page 2-4).
Is
01
B N displayed on the control panel of the 9401 System Unit?
No
Yes
! Go to step 5 of this procedure.
2 Select the IPL type and mode from the control panel of the 9401 System Unit.
a. Press the Up (
f)
or Down
0)
pushbutton until
02
appears
in
the Function/Data display.
b.
Press Enter on the control panel.
Function/Data
I
02
B
MI
"1f-
~
Enter
~
Q.._Q
- -
- -
- -
-
-
RV3D277-0
c. Press the Up
(f)
or Down
0)
pushbutton until B N appears in the Function/Data display.
d. Press Enter on the control panel.
3 Verify that you have selected to perform an IPL from disk (8) in Normal mode (N).
a.
Press the Up 0) or Down 0) pushbutton until
01
appears
in
the Function/Data display.
b.
Press Enter on the control panel.
4 Does B N appear in the Function/Data display?
Yes
No
Use Function 02 to select the IPL type and mode.
Return to step 2 of this procedure.
5 Are you using a nonprogrammable workstation as the system console?
No
Yes
! Ensure that the workstation is powered on.
Go to step 8 of this procedure.
©Copyright
IBM
Corp. 1995
6-1