014 (continued)
DID RUNNING THE SETUP PROGRAM CORRECT THE PROBLEM?
Yes No
015
Replace the battery.
Note: Run the Configuration Utility by selecting 3 (SETUP) and set
the date and time to remove any 16X errors.
If the symptom remains, replace the system board.
016
Check the battery for at least 2.8 V dc.
DOES THE BATTERY HAVE AT LEAST 2.8 V DC?
Yes No
017
Replace the battery.
018
(From step 007)
You have successfully completed the Advanced Diagnostics tests. If you
suspect an intermittent problem, start an error log. If you need instructions,
refer to “Error Log” on page 3-9.
019
(From step 009)
This error message indicates the system date and time are not set.
– Make a note of any error messages and press Esc.
DID THE ERROR MESSAGE GO AWAY WHEN ESC WAS PRESSED?
Yes No
020
Go to “MAP 0300: Keyboard” on page 2-54.
Diagnostic Information 2-33