920  Communications Diagnostic Tests 
This procedure uses SSP procedures (for example, PROBLEM) to diagnose communications problems. 
Diagnostic tests for 
data 
communications attempt to locate problems with internal 
and 
some external 
data 
communications interfaces.  There are four types 
of 
diagnostic tests for 
data 
communications: 
•  Diagnostic tests during IPL 
•  Diagnostic tests during 
on 
line problem determination 
•  Diagnostic tests during concurrent maintenance 
•  Diagnostic tests during customer setup (CSU) 
Diagnostic Tests During IPL 
Diagnostic tests during IPL test the communications hardware; 
data 
is 
wrapped through the line adapters. 
Diagnostic Tests During 
On 
line Problem Determination 
Diagnostic tests during 
on 
line problem determination (pROBLEM) test the communications hardware, 
microcode, and local and remote work stations. 
See 
the manual System Problem Determination - 5363 for 
procedures. 
Diagnostic Tests During Concurrent Maintenance 
Concurrent diagnostic tests are run under SSP while the system 
is 
operating 
on 
other jobs.  Only the line 
being tested must be assigned to the test when these tests are run.  The other lines can 
be 
used for system 
data 
communication. 
Concurrent diagnostic tests include: 
•  SDLCTEST:  The SDLC on line test verifies correct operation 
of 
the communications link between two 
systems, 
or 
between the system and attached SDLC devices. 
See 
"955  Running the SDLC On line Test" 
on 
page  9-9. 
•  BSCTEST:  The BSC on line test verifies correct operation 
of 
the communications link between two 
systems, 
or 
between the system and attached BSC devices. 
See 
"950  Running the BSC On line Test" 
on 
page  9-8. 
•  ST ATEST:  The station test verifies correct operation 
of 
the communications link between the system 
and the remote work stations. 
Note:  When 
STATEST 
is 
started to test a switched line, the primary station (host) waits for a call from 
the secondary station (remote) to start the station test. 
STATEST is 
run 
on 
a line 
that 
is 
varied 
on 
and 
runs concurrent with other traffic 
on 
the line. 
•  COMMTEST:  The communications concurrent diagnostic test has the following option: 
Basic communications diagnostic test:  This test checks 
out 
the communications hardware and 
external cables where possible.  All lines must be varied off. 
Diagnostic Tests During Customer Setup 
Diagnostic tests during customer setup (CSU) test the communications hardware; 
data 
is 
wrapped through 
the line adapters. 
9-4  5363  Maintenance Information