322 Reloading the SSP Diskettes
Note: Reloading the SSP diskettes
is
a customer task.
1.
Ensure that the Security switch
is
in the Service position.
2.
Insert the first SSP diskette (SSPOl).
3.
Select function 2 (Reload).
The 4-character display contains
0000.
If
the Start Function key is pressed now, a normal reload
of
the
SSP diskettes will occur. To bypass the wrap tests, alter the 4-character display to
FFOO.
4.
Press the Start Function key. Follow the displayed instructions to load the SSP diskettes to disk.
5.
Inform the customer that he or she can now reload the program products/utilities beginning with task 2
in the manual
Performing the First System Configuration/or Your
System-5363,
SC21-9686.
324 Reloading the System Microcode Without Auto Configure
1.
Ensure that the Security switch
is
in the Service position.
2.
Insert the diagnostic diskette (diskette
61).
3.
Select function 3 (IPL Diagnostic Diskette).
The 4-character display contains
0000.
If
the Start Function key
is
pressed now, a normal diskette IPL
will occur. To bypass the wrap tests, alter the 4-character display to
FFOO.
4.
Press the Start Function key. The
DCP
Main menu is displayed.
5.
Select the System Customize option from the
DCP
Main menu.
Note: System customize destroys all microcode patches (including free-lance patches) on the disk.
If
these patches are needed, you must apply them again.
6.
Follow the prompts.
7.
When this procedure
is
completed,
and
you were sent here from "Procedure 121" on page 1-5, return to
procedure
"Disk Drive Reload" on page
1-5.
Note:
If
Auto Configure is required,
see
"321 Auto Configuring the System" on page 3-7.
3-8 5363 Maintenance Information