Page #83 background imageLoading...
Page #83 background image
S.
Display Key
Test
a. Press the Select
Function
key
and
select function E
(Compare
Address
and
Stop).
b.
Press the
Display
key.
If
the
Output
display is
blank,
except
for
a 0
or
1
in
the
rightmost position, the
control
panel
is
correct.
Continue
with
step Sb.
If
the
control
panel
is
not
correct, suspect
the
following
FRU:
%
I FRU
99
If
the
Output
Display
light goes
on,
continue
with
step
Sc.
If
the
Output
Display light
does
not
go
on,
go
to
step Sd.
c.
Press the Display key again.
If
the
Output
Display light goes off,
go
to
step
Se.
If
the
Output
Display light does
not
go
off,
continue
with
step Sd.
d.
The
control
panel
is
not
operating
correctly. Suspect the following
FRUs:
%
FRU
8S
Control
panel
10
Operator
panel
cable
S
AIF2
e. Set the Security switch
to
the
Normal
position
(only the
Power
On
light is on). Press
each
of
the
four
input
keys
and
the Display key several times.
If
the
control
panel
does
not
change,
go
to
"lOS System
Entry
Procedure"
on
page
1-2.
If
the
control
panel
changes
in
any
way,
or
if
the
Power
On
light was
not
the
only light
on,
suspect the
following
FRUs:
%
FRU
8S
Control
panel
10
Operator
panel cable
S
AIF2
Section
5.
Control Panel Procedures 5-7

Table of Contents

Other manuals for IBM System/36

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/36 and is the answer not in the manual?

IBM System/36 Specifications

General IconGeneral
BrandIBM
ModelSystem/36
CategoryDesktop
LanguageEnglish

Related product manuals