Table 2. Minimum DCS3700 software and firmware levels (continued)
Software/firmware Level
Drive firmware You can find the latest software and firmware at the IBM System
Storage Support Web site:
www.ibm.com/servers/storage/support/disk/
To find the latest Storage Manager software, controller firmware, NVSRAM, ESM firmware, and drive
firmware, check the firmware readme files.
See the IBM System Storage DS
®
Storage Manager Version 10 Installation and Host Support Guide for your
operating system for instructions that describe how to install the DS Storage Manager host software.
If you need further assistance, please contact your IBM reseller or IBM representative to find out which
controller firmware to use for DCS3700 attachment.
For more information about the DCS3700 parts replacement procedure and problem troubleshooting,
please refer to “Solving problems” on page 129.
Determining firmware levels
There are two different methods to determine the DCS3700 storage system and DCS3700 expansion
enclosure firmware versions. Each method uses the DS Storage Manager client that manages the DCS3700
storage subsystem with the attached storage expansion enclosure.
Method One:
Go to the Subsystem Management window and select View Storage Subsystem Profile. When the
Storage Subsystem Profile window opens, select the All tab and scroll through Profile For Storage
Subsystem to locate the following information.
Note: The Profile For Storage Subsystem windows contains all the profile information for the entire
subsystem. Therefore, it may be necessary to scroll through a large amount of information to locate
the firmware version numbers.
DSC3700 storage system
v NVSRAM version
v Firmware version
Drives
v Drive Firmware version
DCS3700 expansion unit
v ESM card firmware version
Method Two:
Complete the appropriate procedure to obtain the specified firmware version.
To obtain the controller firmware version:
Click on the Controller icon in the left pane of the Physical View tab of the Subsystem
Management window. The properties of the controller will be displayed in the right pane of the
Physical view tab.
You must perform this step for each individual controller.
16 IBM System Storage DCS3700: Installation, User, and Maintenance Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System Storage DCS3700 and is the answer not in the manual?

IBM System Storage DCS3700 Specifications

General IconGeneral
BrandIBM
ModelSystem Storage DCS3700
CategoryStorage
LanguageEnglish

Related product manuals