EasyManuals Logo

IBM System Storage DCS3700 User Manual

IBM System Storage DCS3700
202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
1. Connect the DCS3700 expansion enclosure to controller A:
a. Connect one end of a SAS cable to the drive expansion port on controller A.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot A in the DCS3700 expansion enclosure.
2. Connect the DCS3700 expansion enclosure to controller B:
a. Connect one end of a SAS cable to the drive expansion port on controller B.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot B in the DCS3700 expansion enclosure.
Figure 34 on page 53 shows a DCS3700 storage system configured with a single DCS3700
expansion unit.
To connect the DCS3700 storage system RAID controllers A and B to multiple DCS3700 expansion
enclosures, complete the following steps:
1. Connect the DCS3700 expansion enclosure to controller A:
a. Connect one end of a SAS cable to the drive expansion port on controller A.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot A in the first DCS3700 expansion enclosure.
2. Connect the of the DCS3700 expansion enclosure to the next DCS3700 expansion enclosure in the
chain:
a. Connect one end of a SAS cable to the Out () SAS connector on the ESM located in SBB slot A of
the DCS3700 expansion enclosure that you just connected.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot A in the next DCS3700 expansion enclosure in the chain.
3. Connect the last DCS3700 expansion enclosure in the chain to controller B:
a. Connect one end of a SAS cable to the drive expansion port on controller B.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot B in the last DCS3700 expansion enclosures of the chain that you created.
4. Connect the second DCS3700 expansion enclosure to the first DCS3700 expansion enclosure.
a. Connect one end of a SAS cable to the Out () SAS connector on the ESM located in SBB slot B of
the second DCS3700 expansion enclosure.
b. Connect the other end of the SAS cable to one of the In () SAS connectors on the ESM located in
SBB slot A of the first DCS3700 expansion enclosure.
Figure 35 on page 54 shows a DCS3700 storage system configured with two DCS3700 expansion
units.
52 IBM System Storage DCS3700: Installation, User, and Maintenance Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System Storage DCS3700 and is the answer not in the manual?