Page #117 background image
Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
089-802-xxx CPU CPU Stress Test Aborted System resource
availability error.
1. Turn off and restart the system.
2. Make sure that the DSA code is at
the latest level. For more information
and to download the utilities, go to
http://www.ibm.com/systems/support/
supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-DSA.
3. Run the test again.
4. Make sure that the system firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For the
latest level of firmware, go to
http://www.ibm.com/support/
docview.wss?uid=psg1 MIGR-4JTS2T
and select your system to display a
matrix of available firmware.
5. Run the test again.
6. Turn off and restart the system if
necessary to recover from a hung
state.
7. Run the test again.
8. Make sure that the system firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 267.
9. Run the test again.
089-802-xxx CPU CPU Stress Test Aborted System resource
availability error.
1. Replace the following components
one at a time, in the order shown,
and run this test again to determine
whether the problem has been
solved:
a. (Trained service technician only)
Microprocessor board
b. (Trained service technician only)
Microprocessor
2. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 3. Diagnostics
97

Table of Contents

Other manuals for IBM System x3100 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 and is the answer not in the manual?

IBM System x3100 M4 Specifications

General IconGeneral
MemoryUp to 32 GB DDR3 ECC UDIMM
Memory Slots4 DIMM slots
Form FactorTower
ChipsetIntel C202
Processor Sockets1
ProcessorIntel Xeon E3-1200 v2 series, Intel Pentium series, Intel Celeron series
StorageUp to 4x 3.5-inch
Power Supply350W
Hard Drive Bays4 x 3.5"
RAID SupportRAID 0, 1, 10
Network InterfaceGigabit Ethernet
Expansion Slots1 x PCIe 3.0 x16, 1 x PCIe 2.0 x4
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server