Installing the upper bezel
This procedure applies only to the 5U server model with hot-swap power supplies
(Model name: 2582-F4x).
To install the upper bezel on the 5U server model with hot-swap power supplies
(Model name: 2582-F4x), complete the following steps.
1. Insert the two tabs on the right-side of the upper bezel into the corresponding
holes on the right side of the chassis.
Bezel clips
2. Rotate the upper bezel to the left side of the chassis until the bezel clips are
aligned with the corresponding indentations on the left side of the chassis and
snap them into place.
3. Install the lower bezel (see “Installing the lower bezel” on page 173).
4. Install and lock the side cover (see “Installing the side cover” on page 167).
5. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Chapter 5. Removing and replacing server components 175

Table of Contents

Other manuals for IBM System x3100 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 and is the answer not in the manual?

IBM System x3100 M4 Specifications

General IconGeneral
MemoryUp to 32 GB DDR3 ECC UDIMM
Memory Slots4 DIMM slots
Form FactorTower
ChipsetIntel C202
Processor Sockets1
ProcessorIntel Xeon E3-1200 v2 series, Intel Pentium series, Intel Celeron series
StorageUp to 4x 3.5-inch
Power Supply350W
Hard Drive Bays4 x 3.5"
RAID SupportRAID 0, 1, 10
Network InterfaceGigabit Ethernet
Expansion Slots1 x PCIe 3.0 x16, 1 x PCIe 2.0 x4
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server

Related product manuals