v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, System x3200 Types 4362 and 4363,” on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code Description Action
1802 No more I/O space is available for a PCI
adapter.
1. If the error code indicates a particular PCI or
PCI-E slot or device, remove that device.
2. If the error remains, reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
1803 No more memory (above 1 MB for a PCI
adapter).
1. If the error code indicates a particular PCI or
PCI-E slot or device, remove that device.
2. If the error remains, reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
1804 No more memory (below 1 MB for a PCI
adapter).
1. Remove the failing adapter.
2. Reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
1805 PCI option ROM checksum error.
1. Remove the failing adapter.
2. Reseat each adapter.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Failing PCI adapter
b. (Trained service technician only) System
board
Chapter 2. Diagnostics 23