EasyManuals Logo

IBM System x3650 M3 4255 Service Guide

IBM System x3650 M3 4255
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Types 4255, 7945, and 7949 server,” on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem
.ElementName)
Error A bus uncorrectable error has
occurred.
(Sensor = Critical Int CPU)
1. Check the system-event log.
2. Check the microprocessor
error LEDs.
3. Remove the failing
microprocessor from the
system board.
4. Check for a UEFI firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5. (Trained service technician
only) Make sure that the two
microprocessors are
matching.
6. (Trained service technician
only) Replace the system
board.
A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem
.ElementName)
Error A bus uncorrectable error has
occurred.
(Sensor = Critical Int DIM)
1. Check the system-event log.
2. Check the DIMM error LEDs.
3. Remove the failing DIMM
from the system board.
4. Check for a UEFI firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5. Make sure that the installed
DIMMs are supported and
configured correctly.
6. (Trained service technician
only) Replace the system
board.
Chapter 3. Diagnostics 123

Table of Contents

Other manuals for IBM System x3650 M3 4255

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M3 4255 and is the answer not in the manual?

IBM System x3650 M3 4255 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel 5520
Max Processors2
ProcessorIntel Xeon 5600 series
MemoryUp to 192GB DDR3
Network InterfaceDual-port Gigabit Ethernet
Hard Drive BaysUp to 16 x 2.5" or 6 x 3.5"
RAID SupportRAID 0, 1, 10
Memory Slots18 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware

Related product manuals