Table 10. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, Types 4255, 7945, and 7949 server,” on page 157 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Sensor Sys Board Fault has
transitioned to critical from a less
severe state.
Error A sensor has changed to Critical
state from a less severe state.
1. Check the system-event log.
2. Check for an error LED on
the system board.
3. Replace any failing device.
4. Check for a UEFI firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
5. (Trained service technician
only) Replace the system
board.
The Power Supply (Power Supply:
n) has Failed.
(n = power supply number)
Error Power supply nhas failed.
(n = power supply number)
1. If the power-on LED is lit,
complete the following steps:
a. Reduce the server to the
minimum configuration
(see “Power-supply LEDs”
on page 69).
b. Reinstall the components
one at a time, restarting
the server each time.
c. If the error recurs, replace
the component that you
just reinstalled.
2. Reseat power supply n.
3. Replace power supply n.
(n = power supply number)
Sensor PS n Fan Fault has
transitioned to critical from a less
severe state.
(n = power supply number)
Error A sensor has changed to Critical
state from a less severe state.
1. Make sure that there are no
obstructions, such as bundled
cables, to the airflow from the
power-supply fan.
2. Replace power supply n.
(n = power supply number)
124 IBM System x3650 M3 Types 4255, 7945, and 7949: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3650 M3 4255

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M3 4255 and is the answer not in the manual?

IBM System x3650 M3 4255 Specifications

General IconGeneral
Form Factor2U Rack
ChipsetIntel 5520
Max Processors2
ProcessorIntel Xeon 5600 series
MemoryUp to 192GB DDR3
Network InterfaceDual-port Gigabit Ethernet
Hard Drive BaysUp to 16 x 2.5" or 6 x 3.5"
RAID SupportRAID 0, 1, 10
Memory Slots18 DIMM slots
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware