Loading...
N Voice set mode
Sets the automatic monitor function, short play and
normal recording times for voice recorder.
q Push [EXIT/SET] several times to close a multi-
function screen, if necessary.
w Push [VOICE] (F-2) to call up the voice recorder
screen.
e Push [EXIT/SET] to select voice recorder menu.
r Push [SET] (F-6) to select voice set mode screen.
t Push [Y] (F-1) or [Z] (F-2) to select the desired
item.
y Rotate the main dial to set the desired condition or
value.
Push and hold [DEF] (F-4) for 1 sec. to select the
default condition or value.
u Push [EXIT/SET] to exit the voice set mode
screen.
F-1 F-2 F-4
EXIT/SET
Main dial
DEF
Auto Monitor ON
Turn on the automatic monitor function for recorded
audio contents transmission.
• ON : Monitors transmit audio automatically when
sending a recorded audio.
• OFF : Monitors transmit audio only when the mon-
itor function is in use.
Short Play Time 5s
Set the desired time period for one-touch playback
(when [PLAY] is pushed momentarily).
3 to 10 sec. in 1 sec. steps can be set.
(default: 5 sec.)
Normal Rec Time 15s
Set the desired time period for one-touch recording
(when [REC] is pushed momentarily).
5 to 15 sec. in 1 sec. steps can be set.
(default: 15 sec.)
97