SPECIFICATIONS
General
• Minimum range: 25 m, 82 ft (when measurement range is
1
8 NM)
• Maximum range: 36 NM
• Measurement range:
1
8,
1
4,
1
2,
3
4, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 36 (NM)
• Preheat time:
90 seconds
Connection length between display and scanner unit
: 15 m, 49.2 ft
Display unit
• LCD display: 10.4-inch TFT Color LCD
• Resolution: 480 × 640
• LCD mounting: Vertical
• Input: NMEA 0183 format (for navigation receiver),
N+1 format (uxgate compass sensor),
AUX,
IEC61162-2 format (for AIS unit)
• Output: NMEA 0183 format
• Power supply requirement: 10.2 to 42 V DC
• Power consumption (at zero wind velocity): Approximately 55 W
• Usable temperature range: –15˚C to +55˚C, +5˚F to 131˚F
• Dimensions (Mounting bracket is included):
301 (W)
× 323.5 (H) × 119.2 (D) mm,
(Projections are not included) 11.8 (W) × 12.7 (H) × 4.7 (D) inches
• Weight (Mounting bracket is included): Approximately 4.3 kg, 9.5 lb
Scanner unit (EX-2714)
• Type: 60 cm (2 ft.)
Slotted Waveguide Array, enclosed in a radome.
• Rotation speed (typical): 24 rpm, 36 rpm
• Beam width (typical): Horizontal beam
Vertical beam 22˚
• Side lobe (typical): –22 dB
• Polarization: Horizontal
• Transmission frequency: 9410 MHz ±30 MHz P0N
• Peak output power: 4 kW
• Pulse width:
80 ns / 2160 Hz, 80 ns / 1440 Hz, 250 ns / 1440 Hz, 350 ns
/
1440 Hz, 350 ns / 720 Hz, 900 ns / 720 Hz
• Mixer and Local Oscillator: Microwave Integrated Circuit
• Transmitting Tube: Magnetron MAF1421B
• Modulator: FET switching
• Duplexer: Circulator
• Tuning system: Automatic / manual selectable
• Intermediate frequency: 60 MHz
• IF Band width: 10 MHz, 3 MHz
• Dimensions:
640 (W)
× 256 (H) × 640 (D) mm,
25.2 (W) × 10.1 (H) × 25.2 (D) inches
• Usable temperature range: –25˚C to +70˚C, –13˚F to 158˚F
• Relative Humidity: Less than 95% at 40˚C (+104˚F)
• Weight: Approximately 8 kg, 17.5 lb (without cable)
Options
OPC-2339 system cable
Allows you to install the display unit and scanner up to 20 m (65.6 ft) apart.
OPC-2340 system cable
Allows you to install the display unit and scanner up to 30 m (98.4 ft) apart.
UX-252 video output unit
Allows you to connect an external display or a PC monitor with a VGA connector.
All stated specications are subject to change without notice or obligation.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Table of Contents

Other manuals for Icom MR-1010RII

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom MR-1010RII and is the answer not in the manual?

Icom MR-1010RII Specifications

General IconGeneral
BrandIcom
ModelMR-1010RII
CategoryMarine Radar
LanguageEnglish

Related product manuals