14: T
ROUBLESHOOTING
14-2 S
MART
AXIS P
RO
/L
ITE
U
SER
'
S
M
ANUAL
FT9Y-B1378
3. On the right of the Error Status in the PLC Status dialog box, click the Details button.
The PLC Error Status screen appears.
Clearing Error Codes from WindLDR
After removing the cause of the error, clear the error code using the following procedure:
1. From the WindLDR menu bar, select Online > Monitor > Monitor. The monitor mode is enabled.
2. From the WindLDR menu bar, select Online > Status. The PLC Status dialog box appears.
3. On the right of the Error Status in the PLC Status dialog box, click the Clear button.
This procedure clears the error code from special data register D8005 (general error code), and the error is cleared from the PLC
Status dialog box.
Error Cleared
Clear Button