Section: 8
IDS X64 User Manual 700-398-01D Issued August 2010
Hold down the [P] key until the beep
¾ If the [P] key is pressed until the keypad beeps (approximately 1 second) a PANIC ALARM
condition will be activated.
¾ The POWER LED stays on and the ARM LED flashes.
¾ A PANIC ALARM may also be activated using any FIXED PANIC button or a REMOTE PANIC
button (if installed).
¾ If the audible panic option has been selected, the siren will sound. A PANIC ALARM will be
transmitted to the monitoring company.
¾ To silence the siren, enter a valid [USER CODE].
¾ Press the [P] key only in an emergency situation that requires response by emergency
personnel.
Hold down the [M] key until the beep
¾ If the [M] key is pressed until the keypad beeps (approximately 1 second) a MEDICAL ALARM
condition will be activated.
¾ The keypad buzzer will beep 5 times.
¾ A medical reporting code will be reported to the monitoring company.
[#] [DURESS CODE]
¾ This is a special user code that should only be used in the unique situation where an intruder
forces one to disarm the system “under duress”.
¾ When a [DURESS CODE] is entered, the control panel disarms.
¾ A Duress Alarm Code (if programmed) will be reported to the monitoring company.
¾ It is advisable to choose a Duress code that can be easily remembered by all family (or staff)
members.
Hold down the [0] key until the beep
The Alarm Memory displays any zones that were violated, tampered with, or bypassed during the last
arm cycle. A flashing ARM LED notifies the user of an alarm memory condition. To view the alarm
memory, disarm the panel and continue as follows:
1. Hold down the [0] key until the keypad buzzer sounds.
2. The POWER LED will turn off and the keypad buzzer will sound briefly.
3. Zone LEDs that are on show which zones were violated during the last armed period.
4. Press the [1] key followed by the [*] key to return to violated zones.
5. Press the [2] key followed by the [*] key to display zones that were bypassed.