26
Resolution
0.1V
Accuracy
±(0.2% of setting + 3counts)
Current
Range
0.05A~19.50A
0.05A~39.00A
Resolution
0.01A
Accuracy
± (1% of reading +5counts)
Power
Range
0W~3900W
0W~7800W
Resolution
1W
Accuracy
± (2% of reading +5counts)
Protection
Software OCP
Over Current 110% of full rated current >1 second
Output Short Shut Down Speed (*7)
<1 second
Software OPP
When over Power 105 ~ 110% of full power >5 second.
When over Power >110% of full power <1 second.
Software OTP
Temperature over 95°C on the power amp
and PFC heatsink
Temperature over 120°C on the power amp
and PFC heatsink
Software OVP
L
When output frequency <100Hz, maximum voltage deviation +5V
When output frequency 101-500Hz, maximum voltage deviation +15V
When output frequency 501-1000Hz, maximum voltage deviation +20V
H
When output frequency <100Hz, maximum voltage deviation +10V
When output frequency 101-500Hz, maximum voltage deviation +30V
When output frequency 501-1000Hz, maximum voltage deviation +40V
Software LVP
L
When output frequency <100Hz, maximum voltage deviation -5V>0.5 second
When output frequency 101-500Hz, maximum voltage deviation -15>0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -20V>0.5 second
H
When output frequency <100Hz, maximum voltage deviation -10V >0.5 second
When output frequency 101-500Hz, maximum voltage deviation -30V >0.5 second
When output frequency 501-1000Hz, maximum voltage deviation -40V >0.5 second
Reverse Current Protect
Over 75W of full power
GENERAL
Safety Agency Listing
CE, cTUVus, RoHS2
Transient (only for 40~70Hz) (*11)
Trans-Volt 0.0-300.0V Resolution 0.1V
Trans-Site 0~359 Resolution 1
Trans-Time 0.5-999.9mS Resolution 0.1mS
Trans-Cycle 0-9999, 0-Constant
Operation Key Feature
Soft key, Numeric key, Rotary Knob.
Remote Input Signal
Test, Reset, Interlock(*12),Recall program memory 1 through 7
Remote Output Signal
Pass, Fail , Test-in Process
Key Lock
Yes, Password Driven
Memory
50 memories, 9 steps/memory
Ext Trigger
START / END / BOTH / OFF in the Program mode, Output Signal 5V ,BNC type