INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Parameter
ID
Description Range Default
Customised
value
U 11 Night function
is function can only be activated if CARV2 (op-
tional) is available.
Activating the function allows you to reduce the
compressor frequency during the outdoor unit
operation in the time slot set in the U 12 and U 13
parameters.
Make sure the additional power sources needed to
meet potential requirements that may present
themselves during active operation are available
(e.g. add it iona l resistanc es)
OFF - ON OFF
U 12 Night function enabling time 0 ÷ 23 0
U 13 Night function disabling time 0 ÷ 23 0
U 14 Zone 3 heating ow set point in case of no thermal regulation (“R 01” = OFF). 20 ÷ 80 °C 25
U 15 Zone 2 cooling ow set point in case of no thermal regulation (“R 01” = OFF) 5 ÷ 25 °C 20
U 16 Zone 3 central heating oset - 15 ÷ + 15 °C 0
U 17 Zone 3 cooling oset - 15 ÷ + 15 °C 0
U 18 Zone 3 humidity setpoint 30 ÷ 70 50
U 21 Hour setting (internal clock) 0 - 23 hours
U 22 Minutes setting (internal clock) 0 - 59 minutes
U 23 Day of the week
Mo-Tu-We-
- Fr-Sa-Su
U 24 Current day 1 ÷ 31
U 25 Current month 1 ÷ 12
U 26 Current year 00 ÷ 99
U 32 Start time of the DHW recirculation function (do not use) 0 - 23 hours
U 32 Start time of the DHW recirculation function 0 - 23 hours
U 33 Start time of the DHW recirculation function (do not use) 0 - 23 hours
U 50 Venting
In the case of new central heating systems and in
p a r t i c u l a r m o d e f o r o or s y s t e m s , i t i s v e r y i m p o r -
tant that de-aeration is performed correctly. e
function consists of the cyclic activation of the
pump (100 s ON, 20 s OFF) and the 3-way valve
(120 s D.H.W., 120 s heating system).
OFF - ON OFF
e parameters referring to zone 2 can only be displayed
if there is a zone 2 on the system and it is congured cor-
rectly.
e parameters referring to zone 3 can only be displayed
if there is a zone 3 on the system and it is congured cor-
rectly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas MAGIS COMBO PLUS V2 Series and is the answer not in the manual?

Immergas MAGIS COMBO PLUS V2 Series Specifications

General IconGeneral
BrandImmergas
ModelMAGIS COMBO PLUS V2 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals