INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
3.6 STORAGE TANK UNIT
e indoor unit is prepared for connect ion to a storage tank unit,
which must be connected to terminals 37 and 38 of the terminal
board (placed inside the connections compartment), eliminating
resistance R8.
3.7 SYSTEM FILTER
e indoor unit has a lter on the system return cock to keep the
system in good operating conditions.
Periodically and when necessary, the lter can be cleaned as de-
scribed below (Fig. 64).
Close the tap (3) with a size 12 spanner and tap (5) by hand, drain
out the water contained in the indoor unit using the draining
valve (4).
Open the cap (1) and clean the lter (2).
1
2
3
5
4
64