92
INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
4.2 MAGIS COMBO 4 PLUS V2 PRODUCT
FICHE IN COMPLIANCE WITH
REGULATION 811/2013
For proper installation of the device, refer to chapter 1 of this
booklet (for the installer) and current installation regulations. For
proper maintenance refer to chapter 3 of this booklet (for the
maintenance technician) and adhere to the frequencies and meth-
ods set out herein.
58
53
55
74
Low temperature (30/35)
Parameter Value Colder zones Average zones Hotter zones
Annual energy consumption for the central heating mode (Q
HE
)kWh\year 2768 2243 1125
Room central heating seasonal eciency ( η
s
)ηs %140181235
Nominal heat output kW 4,00 5,00 5,00
Average temperature (47/55)
Parameter Value Colder zones Average zones Hotter zones
Annual energy consumption for the central heating mode (Q
HE
)kWh\year 3982 3163 1753
Room central heating seasonal eciency ( η
s
) ηs % 96 128 150
Nominal heat output kW 4,00 5,00 5,00