INSTALLER
USERMAINTENANCE TECHNICIAN
TECHNICAL DATA
Installation standards
is indoor unit can be installed outdoors in a partially
protected area.
A partially protected area is one in which the indoor unit
is not exposed to the direct action of the weather (rain,
snow, hail, etc.).
is type of installation is possible when permitted by
the laws in force in the appliance's country of destina-
tion.
Installation of gas appliances, ue ex-
haust pipes and combustion air intake
pipes is forbidden in places with a re
risk (for example: garages, closed park-
ing stalls), and in potentially dangerous
places.
Do not install on the vertical projection
of hobs.
Do not install in places/rooms that con-
stitute public areas of apartment build-
ings, internal stairways or other escape
routes (e.g. oor landings, entrance
halls, etc.).
Installation is also forbidden in places/
rooms that constitute public areas of
apartment buildings such as cellars, en-
trance halls, attics, los, etc., unless oth-
erwise provided for by local regulations
in force.
In any conguration do no install the in-
door unit and outdoor unit at altitudes
above 2000 m.
To prevent electrocution, re or injury,
always switch o the unit, disable the
protective switch and, if smoke escapes
or if the unit is extremely noisy, contact
the Authorised Aer-Sales Technical
Assistance Centre.
Pay attention not to generate sparks as
follows:
Do not remove the fuses while the unit
is on.
Do not unplug the unit while it is on.
It is recommended to install the outlet
high up. Lay the cables in such a way that
they do not get tangled.
Wa l l m ou nt i n g of t h e i nd o or u n i t mu s t g u a r a n te e s t a bl e
and ecient support for the generator.
e plugs (standard supply) are only to be used to x the indoor
unit to the wall; they only ensure adequate support if inserted cor-
rectly (according to technical standards) in walls made of solid or
semi-hollow brick or block. In the case of walls made from hollow
brick or block, partitions with limited static properties, or in any
case walls other than those indicated, a static test must be carried
out to ensure adequate mount.
is indoor unit is used to heat water to below boiling
temperature in atmospheric pressure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas MAGIS COMBO PLUS V2 Series and is the answer not in the manual?

Immergas MAGIS COMBO PLUS V2 Series Specifications

General IconGeneral
BrandImmergas
ModelMAGIS COMBO PLUS V2 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals