29
Page 29 - 6 Tank Sentinel Setup Programming Guide
NOTE:
Diagnostic text
in the left column, is shown
bolded
{ become alarms if active for 48 hours }
#
Printed / Faxed / Displayed
Alarm / Warning Text:
Alarm Type:
System WARNING / Error Descriptions and
ALARM Descriptions
(actions to take)
61
SENSOR SYNC ERROR /
SENSOR SYNC / SEN SYN
SYSTEM
WARNING - data signals not synchronous from
BriteSensor @ Channel #N
(call service provider
ASAP to correct this)
62
CORRECTION (STRAPPING)
TABLE ERROR / TABLE ERR
/ TBL ERR
SYSTEM
WARNING - Tank Strapping Chart or Table...
setup Error (call service provider to correct)
63
TEMPERATURE ERROR /
TEMP ERROR /
TMP ERR
SYSTEM
WARNING - probe/product Temperature -
calculation Error (
TMP ERR
call service provider
to correct this problem)
64
THEFT DETECTED / THEFT
LIMIT
SYSTEM
WARNING - Sentinel Mode: Theft Detected (the
amount of product missing reached the Theft Limit)
alarm report for Tank N
65
TS-SEM FUSE OPEN / SEM
FUS / SEM FUSE
SYSTEM
WARNING - TS-SEM FUSE OPEN @ BriteBox #1
or #2... [#1 is closest to the console] there is no 5
VDC Leak Detection Sensors wired to the
BriteBox won't function !
(call service provider to
troubleshoot/replace TS-SEM FUSE F1)
66
UNSTABLE PROBE / UNST
PROBE / UNST PB / UNST
PB
SYSTEM
WARNING - the signal from Probe N has become
Unstable
(call service provider to correct)
67
VOLUME ERROR / VOLUME
ERR / VOL ERR (also see
level, net, ullage, water error)
SYSTEM
WARNING - product - Volume calculation error
(Error in programming: tank shape / probe type /
special probe - OR - no level signal from probe.
Call service provider to correct this.)
68
WATCHDOG TIMEOUT / WD
TIMEOUT
SYSTEM
WARNING - the console self-monitoring program
has detected a software or power quality problem
(this error may happen after hardware upgrades)
69
WATER VOLUME ERROR /
WTR VOL ER / WTR VOL
SYSTEM
WARNING - Water Volume calculation error
(Error in tank shape / probe type or special probe
data - OR - no water float / level signal from probe.
Call service provider to correct this.)
70
HIGH HIGH / HIGH HIGH
LIMIT
TANK
High High product level Limit @ Tank N
(see
procedures at your site about this alarm / overfill)
71
HIGH LIMIT TANK
High product level Limit @ Tank N
(see
procedures at your site about this alarm / overfill)
72
LARGE THEFT TANK
Generated by TS-DIM unit. The amount of product
dispensed exceeded the programmed User
Threashold value, and/or exceeded the number of
Dispensers in use. Also caused by a Catastrophic
Leak. (see policy procedures at your site)
73
LOW LIMIT TANK
Low product level Limit @ Tank N
(see policy
procedures at
y
our site
)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Incon task sentinel TS-508 and is the answer not in the manual?

Incon task sentinel TS-508 Specifications

General IconGeneral
BrandIncon
Modeltask sentinel TS-508
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals