40 Keypads
Anti-intrusion control panels
CODE PARAMETERS
Description: edit field for the code description.
Partitions - select the partitions the user code is assigned to. Press , to enable the
partition and to disable it.
Options - use and to enable/disable the options for each code.
•• Partition filter - if this option is enabled, the code will be able to change the
parameters only of codes with a lower rank in the system hierarchy whose partitions are
amongst the partitions assigned to the code being programmed.
For example, if a code is configured as “Master” with “Partition filter” and is assigned to
partitions 1, 3, 5 and 7, it will be able to enable/disable or change the PIN of a “User”
code assigned to partitions 1 and 5 but not the PIN of a “User” code assigned to
partitions 1, 2, and 3.
•• Text menu and User menu - the combination of these two options allows immediate
visualization of the menu screens on the keypad displays after acceptance of a valid
user code. Refer to the following table.
In all methods of access (A, B and C), the key allows you to access/view the other cases
in succession, see figure.
•• AnnounceShortcut - if enabled on a voice capable keypad, the descriptions of all the
shortcuts assigned to the code and associated with the number keys will be announced
after acceptance of the entered code.
•• Remote access - if enabled, the code PIN can be used to operate the system from any
remote telephone.
If the code PIN is entered on a remote telephone keypad, only the shortcuts associated
with keys 0 to 9 can be used to:
-Arm/Disarm
- Stop alarms
- Clear call queue
- Delete memory
- Activate output
- Deactivate output
- Listen-in
-Arming status
Any other type of command will have no effect.
•• Patrol - if enabled, the code will be able to disable the system for the pre-set “Patrol
time”.
•• Fixed length - if enabled, after typing in a PIN and without pressing the OK key, the
user will be able to activate the shortcut associated with function key F12, programmed
via the “F1/4KeyShortcuts”, to be described later.
If this shortcut is number 1 (“Arm/disarm”) and all the partitions assigned to the user
code in question are disarmed, the command will arm them, otherwise it will disarm
them.
If this option is enabled, the user of the code concerned can access their menu only
after pressing OK and typing-in their PIN.
F1/4KeyShortcuts - this section allows you to configure up to 12 shortcuts associated
with keys , ..., . After valid PIN entry the keypad will show the icons that
correspond to keys , ..., which are associated with these shortcuts. The
respective shortcut will activate when the corresponding key is pressed.
0/9 Key shortcuts - this section allows you to configure up to 10 shortcuts associated
with keys , ..., . After PIN acceptance, the code user can activate the shortcut by
pressing the respective number key.
Table 6-18: Combinations “text menu” and “user menu”
Case Text menu User menu Description
A
Disabled Enabled
Access to the user-menu (shown as a list of oper-
ations the user is enabled to perform); at this
point the user can scroll the list using and
and select the required option.
B
Disabled Disabled
Visualization of the user-icons associated with
function keys , ..., ; at this point the
user can press the required function key and acti-
vate the associated shortcut.
C
Enabled Disabled
Shows the descriptions of the personalized user-
icons associated with function keys. The shortcut
descriptions will be shown instead of the shortcut
icons, at this point the user can use and
to scroll the list of shortcut descriptions
and select the shortcut, which can be activated by
means of the
OK
key.
D
Enabled Enabled The same as “
C
User Code
User Code
Manage alarms
Arm/Disarm op.
Voice functions
User Code
Stop alarms
Delete memory
Nexus status
A