Function
Code
Parameter Name Setting Range Min. Unit Default Property
1: Multi-point V/F curve
F3-01
Torque boost 0.0% (automatic torque boost)–30%
0.1% 1.0% ƿ
F3-02
Cutoff frequency of
torque boost
0.00 Hz to maximum frequency
0.01 Hz 50.00 Hz ƾ
F3-03
V/F frequency 1 (F1) 0.00 Hz to rated motor frequency
0.01 Hz 0.00 Hz ƾ
F3-04 V/F voltage 1 (V1)
0.0%–100.0%
0.1% 0.0% ƾ
F3-05 V/F frequency 2 (F2) V1 to rated motor frequency 0.01 Hz 0.00 Hz ƾ
F3-06 V/F voltage 2 (V2)
F1 to 100.0%
0.1% 0.0% ƾ
F3-07 V/F frequency 3 (F3)
V2 to rated motor frequency
0.01 Hz 0.00 Hz ƾ
F3-08 V/F voltage 3 (V3)
F2 to 100.0%
0.1% 0.0% ƾ
F3-09
V/F slip
compensation
coefficient
0%–200.0%
0.1% 0.0% ƿ
F3-10
utomatic voltage
regulation (AVR)
0: Invalid
1: Valid
2: Valid only during deceleration
1 2 ƿ
F3-11
V/F oscillation
suppression gain
0–100
1
Model
dependent
ƿ
Group F4: Input terminals
F4-00
DI1 function
selection
1 1 ƾ
F4-01
DI2 function
selection
1 2 ƾ
F4-02
DI3 function
selection
1 12 ƾ
F4-03
DI4 function
selection
1 13 ƾ
F4-04
DI5 function
selection
1 0 ƾ
F4-05
DI6 function
selection
1 0 ƾ
F4-06
DI7 function
selection
1 0 ƾ
F4-07
DI8 function
selection
1 0 ƾ
F4-08
DI9 function
selection
1 0 ƾ
F4-09
DI10 function
selection
0: No function
1: Forward RUN (FWD)
2: Reverse RUN (REV)
4: Forward jog
5: Reverse jog
6: Terminal UP
7: Terminal DOWN
8: Coast to stop
9: Fault reset
11: External fault input
12: Multi-speed terminal 1
13: Multi-speed terminal 2
14: Multi-speed terminal 3
16: Acceleration/Deceleration time
selection terminal
18: Frequency source switchover
30:High-speed pulse input (DI5)
41: RUN enabled
42: Motor selection 1
43: Motor selection 2
44: Brake feedback input
Other: Reserved
1 0 ƾ
F4-10
DI filter time 0–100
1 4 ƿ
F4-12
Terminal UP/DOWN
rate
0.01–100.00 Hz/s
0.01 Hz/s 1.00 Hz/s ƾ
F4-13
I1 minimum input
0.00 V to F4-15 0.01 V 0.00 V ƿ
F4-14
I1 minimum input -100.00%–100.0% 0.1% 0.0% ƿ
efesotomas