Function
Code
Parameter Name Setting Range Min. Unit Default Property
F5-10
O1 offset
coefficient
-100.0%–100.0%
0.1% 0.0% ƿ
F5-11
O1 gain -10.00–10.00
0.01 1.00 ƿ
F5-12
O2 offset
coefficient
-100.0%–100.0%
0.1% 0.0% ƿ
F5-13
O2 gain -10.00–10.00
0.01 1.00 ƿ
Group F6: Auxiliary functions 1
F6-00
Crane structure
selection
0: Hoisting structure
1: Traveling structure
1 0 ƾ
F6-01
Open-loop control
mode
0: Mode 0
1: Mode 1
1 1 ƾ
F6-07
cceleration/Decele
ation mode
0: Linear acceleration/deceleration
1: S-curve acceleration/deceleration
1 0 ƾ
F6-10 Stop mode
0: Decelerate to stop
1: Coast to stop
1 0
F6-15 Brake usage 0%–100% 1% 100% ƿ
Group F7: Operation panel and display
F7-06
Load speed display
coefficient
0.0001–6.5000 0.0001 1.0000 ƿ
F7-07
Heatsink
temperature of
inverter module
0. 0–100.0qC 1qC
/ Ɣ
F7-08
Heatsink
temperature of
rectifier module
0.0–100.0qC 1qC
/ Ɣ
F7-09
ccumulative
running time
0–65535 h 1 / Ɣ
F7-10
Software version of
the control board
/ / / Ɣ
F7-11
Software version of
the drive board
/ / / Ɣ
Group F8: Auxiliary functions 2
F8-00
JOG running
frequency
0.00 Hz to maximum frequency 0.01 Hz 2.00 Hz ƾ
F8-01
JOG acceleration
time
0.0–1000.0s 0.1s 20.0s ƾ
F8-02
JOG deceleration
time
0.0–1000.0s 0.1s 20.0s ƾ
F8-03
High-speed hoisting
torque limit
0.0%–150.0% 0.1% 0.0% ƾƾ
F8-04
Unblock time of
hoisting torque limit
0.0–50.0s 0.1s 8.0s ƾƾ
F8-05
Power dip
ride-through action
voltage
80%–500% 1% 90% ƾ
F8-06
Power dip
ride-through filter
coefficient
0–1000 1 500 ƾ
F8-07
Commissioning
mode
0: Normal running
1: Factor commissioning
1 0 ƾƾ