Function
Code
Parameter Name Setting Range Min. Unit Default Property
frequency
FA-13
Slewing stop
switchover frequency
0.00–20.00 Hz 0.01 Hz 0.00 Hz ƾ
FA-19
FWD brake release
current 2
0.0%–100.0% (rated motor current)
0.1% 30.0% ƾ
FA-20
REV brake release
current 2
0.0%–100.0% (rated motor current)
0.1% 30.0% ƾ
FA-21 Brake release time 2 0.0–10.0s 0.1s 0.5s ƾ
FA-22
Brake apply
frequency 2
0.00 Hz to FA-27 0.01 Hz 0.50 Hz ƾ
FA-23 Brake apply time 2 0.0–5.0s 0.1s 0.5s ƾ
FA-24
Brake feedback
delay
0.0–10.0s 0.1s 1.0s ƾ
FA-27
Smooth startup
frequency
0.00–50.00 Hz 0.01 Hz 1.00 Hz ƾ
FA-29
Mechanical brake
release delay
0.0–10.0s 0.1s 0.0s ƾ
FA-30
Low-speed shaft
brake apply delay
0.0–10.0s 0.1s 0.0s ƾ
FA-34
Terminal status
indication
- Ɣ
FA-35
Terminal status
indication
- Ɣ
FA-36
uxiliary function
selection
Bit0: Protection for joystick not
returned to zero
Bit1: Brake safety protection
Bit2: Reserved
Bit3: Reserved
Bit4: Reserved
Bit5: Slewing primary hook anti-sway
Bit6: Low-frequency coast to stop
Bit7: Re-start after stop
Bit8: Braking time sequence
shielding
Bit9: Reserved
Bit10: Low-voltage protection
Bit11: Power dip ride-through
1 1024 ƾ
Group FB: Special crane functions
FB-00
Power limit function
selection
0: Disabled
1: Enabled only upward
2: Enabled
1 0 ƾ
FB-01
Upper limit of
maximum power
0.0%–100.0% 0.1% 100.0% ƾ
FB-02
Lower limit of
maximum power
0.0%–100.0% 0.1% 100.0% ƾ
FB-03
Lowest frequency at
power limit
0.00 to F0-10 (maximum frequency) 0.01 Hz 50.00 Hz ƾ
FB-04
cceleration/Decele
ation time
adjustment
amplitude at power
control
0.0–100.0s 0.1s 0.5s ƾ
FB-14
Minimum effective
time of RUN
0.0–10.0s 0.1s 0.3s ƾ
efesotomas