Intel® Server Board S2400SC TPS Appendix B: Integrated BMC Sensor Tables
Revision 2.0 Intel order number G36516-002
119
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System Status
Assert/De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
BMC Watchdog 0Ah All
Mgmt
System
Health
28h
Digital
Discrete
03h
01 State Asserted Degraded As
Trig
Offset
A -
Voltage Regulator Watchdog
(VR Watchdog)
0Bh All
Voltage
02h
Digital
Discrete
03h
01 State Asserted Fatal
As and
De
Trig
Offset
M X
Fan Redundancy1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As and
De
Trig
Offset
A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh All
Temperatur
e
01h
Digital
Discrete
03h
01 State Asserted Fatal
As and
De
Trig
Offset
M X

Table of Contents

Other manuals for Intel S2400SC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S2400SC and is the answer not in the manual?

Intel S2400SC Specifications

General IconGeneral
BrandIntel
ModelS2400SC
CategoryMotherboard
LanguageEnglish

Related product manuals