Appendix B: Integrated BMC Sensor Tables Intel® Server Board S3420GP TPS
Revision 2.4
Intel order number E65697-010
114
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used to describe a sensor:
- A: Auto-rearm
- M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED
Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S3420GPLC - Server Board Motherboard and is the answer not in the manual?

Intel S3420GPLC - Server Board Motherboard Specifications

General IconGeneral
BrandIntel
ModelS3420GPLC - Server Board Motherboard
CategoryServer Board
LanguageEnglish

Related product manuals