Intel® Server Board S3420GP TPS Appendix B: Integrated BMC Sensor Tables
Revision 2.4
Intel order number E65697-010
115
Table 73. Integrated BMC Core Sensors
Sensor Name
3
Sensor # Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
IPMI Watchdog 03h All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
01 - Hard reset
02 - Power
down
03 - Power
cycle
08 - Timer
interrupt
OK
As –
Trig Offset
A X
Physical Scrty 04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
OK
As and
De
– Trig Offset A
X
04 - LAN least
lost
Degraded
FP Interrupt
(NMI)
05h All
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front
panel
NMI/diagnostic
interrupt
OK
As – Trig Offset A
System Event Log 07h All
Event
Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK As Trig Offset A X
System Event
(System Event)
08h All
System
Event
12h
Sensor
Specific
6Fh
04 – PEF
action
OK
As - Trig Offset A,I X
BB +1.05 PCH 10h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S3420GPLC - Server Board Motherboard and is the answer not in the manual?

Intel S3420GPLC - Server Board Motherboard Specifications

General IconGeneral
BrandIntel
ModelS3420GPLC - Server Board Motherboard
CategoryServer Board
LanguageEnglish

Related product manuals