which can improve the settling time of a large Average Rate. If the scale senses
a large weight change, it will temporarily suspend averaging, jump to the new
weight, and resume averaging. Enter a value of 1-10000 to set the threshold (in
display divisions) at which the dynamic averaging triggers. Enter ‘0’ to disable
dynamic averaging. When disabled, the averaging will never be suspended. The
flashing digit may be incremented by pressing the Lb/Kg button or decremented
by pressing the ZERO button. To move one digit to the left, press the TARE
button. When the display shows the desired number, press the mode button to
continue through the mode menu.
8. The display will show “A. oFF”. Press the Mode button. The display shows the
current setting. The number displayed is the minutes that the scale can remain
idle before it automatically powers down into stand-by mode. Note that when the
scale powers down into stand-by mode in this way, the scale can still be turned
back on with the wireless indicator. Setting this number to “000” will disable the
function, meaning the scale will never automatically go into stand-by mode. The
flashing digit may be incremented by pressing the Lb/Kg button or decremented
by pressing the ZERO button. To move one digit to the left, press the TARE
button. When the display shows the desired number, press the mode button to
continue through the mode menu.
9. The display will show “Prt t”. Press the Mode button. The display shows the
current setting. The number enables the scales different print modes. (0 for on-
demand, 1 for continuous, see ‘serial output’ for more details) The flashing digit
may be incremented by pressing the Lb/Kg button or decremented by pressing
the ZERO button. When the display shows the desired number, press the mode
button to continue through the mode menu.
10. The display will show “PbAUd”. Press the Mode button. The flashing display
shows the current setting of the printer baud rate. The baud rates available are:
1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Press either the
zero button or the lb/kg button to toggle the display through the different settings.
When the desired setting is displayed press the mode button to continue through
the mode menu.
11. Message SCid” will be displayed. Press the Mode button. A number will be
displayed with 3 dashes following it. This is the scale number. The flashing digit
may be incremented by pressing the Lb/Kg button or decremented by pressing
the ZERO button. To move one digit to the left, press the TARE button. When
the desired number is displayed, press the Mode button.
12. Message SCLS” will be displayed. Press the Mode button. The display will show
three dashes and then a number. This number is the total number of scales in
the system. The flashing digit may be incremented by pressing the Lb/Kg button
or decremented by pressing the ZERO button. To move one digit to the left,
press the TARE button. When the desired number is displayed, press the Mode
button. The maximum number of scales is 32.